{"product_id":"astroflame-pfp-fr-graphite-ce-ukca-cartridge-grey-310ml","title":"Astroflame PFP FR Graphite - CE\/UKCA (Cartridge - Grey 310ml)","description":"\u003cp\u003e\u003cstrong\u003eAstroflame PFP FR Graphite - CE\/UKCA (Cartridge - Grey 310ml)\u003c\/strong\u003e\u003c\/p\u003e \u003cspan itemprop=\"description\"\u003e\u003cp\u003e\u003cstrong\u003eKey Points:\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eClassified in most constructions for plastic pipes, cables and combustible pipe insulations.\u003c\/li\u003e \t\u003cli\u003eEasy to apply.\u003c\/li\u003e \t\u003cli\u003eHigh sound insulation.\u003c\/li\u003e \t\u003cli\u003eLow emissions - environmentally and user friendly.\u003c\/li\u003e \t\u003cli\u003eSimple to apply with a smooth surface finish.\u003c\/li\u003e \t\u003cli\u003ePermanently flexible – will accommodate movement up to 12.5%.\u003c\/li\u003e \t\u003cli\u003eNo priming necessary for application to most materials; see the installation instructions for further details.\u003c\/li\u003e \t\u003cli\u003eSuitable for most surfaces, included concrete, bricks, Leca, steel, wood, gypsum, glass, plastics and most non-porous surfaces.\u003c\/li\u003e \t\u003cli\u003eHardens quickly, tack free after 1 hour.\u003c\/li\u003e \t\u003cli\u003eThe fire performance specification of the joint filler has been derived when the joint filler has been allowed to cure for 30 days.\u003c\/li\u003e \t\u003cli\u003eMinimum 12 months storage time.\u003c\/li\u003e \t\u003cli\u003e30 years working life.\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eAstro PFP FR Graphite is a high specification formulation designed to prevent the spread of fire, smoke and gases through openings in fire rated walls and floors. Astro PFP FR Graphite expands when it is subjected to fire and closes openings around penetrations when any combustible or low temperature melting materials have burnt away.\u003c\/p\u003e  \u003cp\u003eAstro PFP FR Graphite is designed to fire seal difficult services which traditional fire rated mastics do not achieve such as large plastic pipes.\u003c\/p\u003e  \u003cp\u003eAstro PFP FR Graphite can be used with a suitable filling material, i.e. stone wool or Astroflame Backing material in order to ensure correct width to depth ratio and to reduce the shrinking of the sealant during curing. Minimum depth and maximum width of the joints are included in the installation instructions. Thermal activation takes place at 150 °C when the material will expand (intumesce) to prevent the passage of fire and smoke for periods up to 4 hours.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eSound Insulation:\u003c\/strong\u003e\u003c\/p\u003e  \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" bgcolor=\"#FFFFFF\" width=\"100%\"\u003e \t\u003ctbody\u003e \t\t\u003ctr class=\"w3-center\" bgcolor=\"#000000\"\u003e \t\t\t\u003ctd width=\"50%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003eDescription\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\t\u003ctd width=\"50%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003eSound reduction\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003eSingle sided seal ≥ 25mm depth\u003c\/td\u003e \t\t\t\u003ctd\u003eRw 53 dB\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003eDouble sided seal ≥ 25mm depth\u003c\/td\u003e \t\t\t\u003ctd\u003eRw \u0026gt; 53 dB\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e  \u003cp\u003eAstro PFP FR Graphite has been tested at EXOVA BM Trada (UKAS accredited); according to EN ISO 10140-2:2010. Usage of any backing material is optional, due to the tests being conducted with sealant only.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eEmission data (indoor air quality):\u003c\/strong\u003e\u003c\/p\u003e  \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" bgcolor=\"#FFFFFF\" width=\"100%\"\u003e \t\u003ctbody\u003e \t\t\u003ctr class=\"w3-center\" bgcolor=\"#000000\"\u003e \t\t\t\u003ctd width=\"33%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003eCompound\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\t\u003ctd width=\"33%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003eEmission rate after 3 days\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\t\u003ctd width=\"33%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003eEmission rate after 4 weeks\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003eTVOC\u003c\/td\u003e \t\t\t\u003ctd\u003e51 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\t\u003ctd\u003e20 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003eTSVOC\u003c\/td\u003e \t\t\t\u003ctd\u003eᐸ 5 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\t\u003ctd\u003eᐸ 5 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003eVOC w\/o NIK\u003c\/td\u003e \t\t\t\u003ctd\u003eᐸ 5 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\t\u003ctd\u003eᐸ 5 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003eR Value\u003c\/td\u003e \t\t\t\u003ctd\u003e0.17\u003c\/td\u003e \t\t\t\u003ctd\u003e0.14\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003eFormaldehyde\u003c\/td\u003e \t\t\t\u003ctd\u003eᐸ 3 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\t\u003ctd\u003eᐸ 3 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003eAcetaldehyde\u003c\/td\u003e \t\t\t\u003ctd\u003eᐸ 3 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\t\u003ctd\u003eᐸ 3 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003eCarcinogenic\u003c\/td\u003e \t\t\t\u003ctd\u003eᐸ 1 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\t\u003ctd\u003eᐸ 1 μg\/m\u003csup\u003e3\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd colspan=\"3\" style=\"width: 33.3333%;\"\u003en.d. or ᐸ means not detected\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e    \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" bgcolor=\"#FFFFFF\" width=\"100%\"\u003e \t\u003ctbody\u003e \t\t\u003ctr bgcolor=\"#000000\"\u003e \t\t\t\u003ctd width=\"50%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003eRegulation or Protocol\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\t\u003ctd width=\"50%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003eConclusion\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eFrench VOC Regulation\u003c\/td\u003e \t\t\t\u003ctd\u003eA+\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eFrench CMR components\u003c\/td\u003e \t\t\t\u003ctd\u003ePass\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eItalian CAM\u003c\/td\u003e \t\t\t\u003ctd\u003ePass\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eABG \/ AgBB to the guidelines of DIBt\u003c\/td\u003e \t\t\t\u003ctd\u003ePass\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eBelgian Regulation\u003c\/td\u003e \t\t\t\u003ctd\u003ePass\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eEMICODE\u003c\/td\u003e \t\t\t\u003ctd\u003eEC 1 PLUS\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eIndoor Air Comfort GOLD \u003csup\u003e®\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\t\u003ctd\u003ePass\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eBlue Angel (DE-UZ 123)\u003c\/td\u003e \t\t\t\u003ctd\u003ePass\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eBREEAM-International\u003c\/td\u003e \t\t\t\u003ctd\u003eExemplary Level\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eBREEAM-NOR\u003c\/td\u003e \t\t\t\u003ctd\u003ePass\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eLEED v4.1\u003c\/td\u003e \t\t\t\u003ctd\u003eCompliant\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e  \u003cp\u003eAstro PFP FR Graphite has been tested by Eurofins Product Testing; reports available upon request.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003ePipe end configurations:\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eWhen testing pipes, one can choose not to cap (or close) the pipe, or cap the pipe inside the furnace, or outside the furnace, or on both sides. The configuration chosen depends on the intended application of the pipe and\/or the installation environment. The code defining if a pipe is capped is stated after the fire classification. For instance EI 60 C\/U which means the pipe was capped inside the furnace, and uncapped outside the furnace. The test configuration defines the approvals possible.\u003c\/p\u003e  \u003cp\u003eOur engineering judgment based on EN 1366-3:2009 are:\u003c\/p\u003e  \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" bgcolor=\"#FFFFFF\" width=\"100%\"\u003e \t\u003ctbody\u003e \t\t\u003ctr bgcolor=\"#000000\"\u003e \t\t\t\u003ctd colspan=\"2\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cstrong\u003eIntended use of pipe\u003c\/strong\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e\u003cfont color=\"#ffffff\"\u003e\u003cstrong\u003ePipe end condition\u003csup\u003e4)\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd rowspan=\"2\"\u003eRainwater pipe, plastic\u003c\/td\u003e \t\t\t\u003ctd\u003eAt drainage\u003c\/td\u003e \t\t\t\u003ctd\u003eU\/U\u003csup\u003e1)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eNot at drainage\u003c\/td\u003e \t\t\t\u003ctd\u003eC\/C\u003csup\u003e2)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd rowspan=\"4\"\u003eDrainage or sewage pipe, plastic\u003c\/td\u003e \t\t\t\u003ctd\u003eVentilated drain\u003c\/td\u003e \t\t\t\u003ctd\u003eU\/U\u003csup\u003e1)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eUnventilated drain\u003c\/td\u003e \t\t\t\u003ctd\u003eU\/C\u003csup\u003e1)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eDrain w\/water trap\u003c\/td\u003e \t\t\t\u003ctd\u003eU\/C\u003csup\u003e1)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eNot at drainage\u003c\/td\u003e \t\t\t\u003ctd\u003eC\/C\u003csup\u003e2)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd colspan=\"2\"\u003ePipe in closed circuit (water, gas, air, electricity etc.)\u003c\/td\u003e \t\t\t\u003ctd\u003eC\/C\u003csup\u003e2)\u003c\/sup\u003e \u003csup\u003e3)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd colspan=\"2\"\u003eFlue gas recovery system pipe, plastic\u003c\/td\u003e \t\t\t\u003ctd\u003eU\/C\u003csup\u003e1)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd colspan=\"2\"\u003ePipe with open ends and ≥ 50cm length on both sides, plastic\u003c\/td\u003e \t\t\t\u003ctd width=\"226px;\"\u003eU\/U\u003csup\u003e2)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd rowspan=\"2\"\u003ePipe supported by suspension system, metal\u003c\/td\u003e \t\t\t\u003ctd\u003eFire rated support\u003c\/td\u003e \t\t\t\u003ctd\u003eC\/U\u003csup\u003e1)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003eNon-fire rated\u003c\/td\u003e \t\t\t\u003ctd\u003eU\/C\u003csup\u003e1)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd colspan=\"2\"\u003eWaste disposal shaft pipe, metal\u003c\/td\u003e \t\t\t\u003ctd\u003eU\/C\u003csup\u003e1)\u003c\/sup\u003e\n\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e  \u003cp\u003e\u003csup\u003e1)\u003c\/sup\u003e Suggested in EN 1366-3:2009. \u003csup\u003e2)\u003c\/sup\u003e Astroflames's judgment based on tests. \u003csup\u003e3)\u003c\/sup\u003e Metal pipes should have fire rated support. \u003csup\u003e4)\u003c\/sup\u003e U\/U classified fire seals cover C\/U, U\/C and C\/C. C\/U classified fire seals cover U\/C and C\/C. U\/C classified fire seals cover C\/C.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eAir Permeability:\u003c\/strong\u003e\u003c\/p\u003e  \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" bgcolor=\"#FFFFFF\" width=\"100%\"\u003e \t\u003ctbody\u003e \t\t\u003ctr class=\"w3-center\" bgcolor=\"#000000\"\u003e \t\t\t\u003ctd width=\"25%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003ePositive Pressure (Pa)\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\t\u003ctd width=\"25%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003eLeakage (m\u003csup\u003e3\u003c\/sup\u003e\/h)\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\t\u003ctd width=\"25%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003eNegative Pressure (Pa)\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\t\u003ctd width=\"25%\"\u003e\u003cfont color=\"#ffffff\"\u003e\u003cb\u003eLeakage (m\u003csup\u003e3\u003c\/sup\u003e\/h)\u003c\/b\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003e25\u003c\/td\u003e \t\t\t\u003ctd\u003e0.00\u003c\/td\u003e \t\t\t\u003ctd\u003e25\u003c\/td\u003e \t\t\t\u003ctd\u003e0.00\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003e50\u003c\/td\u003e \t\t\t\u003ctd\u003e0.00\u003c\/td\u003e \t\t\t\u003ctd\u003e50\u003c\/td\u003e \t\t\t\u003ctd\u003e0.00\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003e100\u003c\/td\u003e \t\t\t\u003ctd\u003e0.00\u003c\/td\u003e \t\t\t\u003ctd\u003e100\u003c\/td\u003e \t\t\t\u003ctd\u003e0.00\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003e200\u003c\/td\u003e \t\t\t\u003ctd\u003e0.00\u003c\/td\u003e \t\t\t\u003ctd\u003e200\u003c\/td\u003e \t\t\t\u003ctd\u003e0.00\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003e300\u003c\/td\u003e \t\t\t\u003ctd\u003e0.00\u003c\/td\u003e \t\t\t\u003ctd\u003e300\u003c\/td\u003e \t\t\t\u003ctd\u003e0.02\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003e450\u003c\/td\u003e \t\t\t\u003ctd\u003e0.03\u003c\/td\u003e \t\t\t\u003ctd\u003e450\u003c\/td\u003e \t\t\t\u003ctd\u003e0.06\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr class=\"w3-center\"\u003e \t\t\t\u003ctd\u003e600\u003c\/td\u003e \t\t\t\u003ctd\u003e0.13\u003c\/td\u003e \t\t\t\u003ctd\u003e600\u003c\/td\u003e \t\t\t\u003ctd\u003e0.12\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e  \u003cp\u003eAstro PFP FR Graphite has been tested at Warringtonfire Testing and Certification Ltd (UKAS accredited); according to EN 1026: 2016.\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003c\/p\u003e  \u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" bgcolor=\"#FFFFFF\" width=\"100%\"\u003e \t\u003ctbody\u003e \t\t\u003ctr bgcolor=\"#ffffff\"\u003e \t\t\t\u003ctd width=\"20%\"\u003e\u003cfont color=\"#000000\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/font\u003e\u003c\/td\u003e \t\t\t\u003ctd width=\"50%\"\u003e\u003cfont color=\"#000000\"\u003eReady for use, water based graphite sealant\u003c\/font\u003e\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eSpecific gravity\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e1.56 - 1.60\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003epH\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e8.00 – 9.50\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eReaction to fire\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003eB - s1, d0\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eFlash point\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003eNone\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eExpansion in fire\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003eApprox. 1 : 25\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eNon-sticky\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e60 minutes\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eFilm forming\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e30 minutes\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eTotally hardened\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e3 to 5 days depending on thickness and temperature, full cure may take up to 30 days\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eFlexibility\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003eLow to medium 12.5% according to ISO 11600\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eDurability\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003eClass Z\u003csub\u003e2\u003c\/sub\u003e intended for internal conditions with humidity classes other than Z\u003csub\u003e1\u003c\/sub\u003e, excluding temperatures below 0°C\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eThermal conduct\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e0.85 W\/mK (+\/- 3%) @ 20mm depth\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eStorage\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e12 months stored in unopened cartridges. To be stored in temperatures between 5°C and 30°C\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eWorking life\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e30 years\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eService temp.\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e-15 to +75°C\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eApplication temp.\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003e+4 to +30°C\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eCompatibility\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003eSuitable for use with most materials, but should not be used In direct contact with bituminous materials\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eLimitations\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003eShould not be used in permanently damp areas or in joints with excessive movement, joints at floor level or joints below the ground\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eClassification\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003eCE-marked - Sealant for fire rated penetrations class EI 240\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e\u003cb\u003eStandard colours\u003c\/b\u003e\u003c\/td\u003e \t\t\t\u003ctd\u003eDark grey (may grow darker during curing)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e  \u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eSingle Cartridge - 310ml\u003c\/li\u003e \t\u003cli\u003eColour: Dark Grey\u003c\/li\u003e \u003c\/ul\u003e                  \u003cp\u003e\u003cb\u003eDownload and review any of the following information:\u003c\/b\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/pdf\/Astro_PFP_FR_Graphite.pdf','_blank');\" type=\"button\" value=\"Product Data Sheet\"\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/pdf\/Astro_PFP_FR_Graphite_SDS.pdf','_blank');\" type=\"button\" value=\"Safety Data Sheet\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eCertification\/Fire Test Reports:\u003c\/strong\u003e\u003c\/p\u003e \u003cimg align=\"left\" alt=\"CE Information\" height=\"32\" hspace=\"7\" src=\"https:\/\/www.astroflame.com\/images\/ce-ukca-icon-stormflame.gif\" vspace=\"40\" width=\"32\"\u003eCE Marked Documents\u003cbr\u003e 'DoP's are 'Declaration of Performance'\u003cbr\u003e 'CoC's are 'Certificate of Constancy of Performance'\u003cbr\u003e 'ETA' European Technical Assessment Sheet\u003cbr\u003e 'TDS' are 'Technical Data Sheet'\u003cbr\u003e 'UKTA' are UK Technical Assessment Sheet \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ce-data\/Astro-PFP-Graphite-DoP.pdf','_blank');\" type=\"button\" value=\"DoP Astro PFP FR Graphite\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ce-data\/Astro-PFP-FR-Graphite-TDS.pdf','_blank');\" type=\"button\" value=\"Astro PFP FR Graphite TDS\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ce-data\/CoC-Astro-PFP-FR-Graphite.pdf','_blank');\" type=\"button\" value=\" CoC Astro PFP FR Graphite CE\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ce-data\/Astro-PFP-FR-Graphite-ETA.pdf','_blank');\" type=\"button\" value=\"Astro PFP FR Graphite ETA CE\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ukca-data\/CoC-UKCA-Astro-PFP-FR-Graphite.pdf','_blank');\" type=\"button\" value=\"CoC Astro PFP FR Graphite UKCA\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ukca-data\/Astro-PFP-FR-Graphite-UKTA.pdf','_blank');\" type=\"button\" value=\"Astro PFP FR Graphite UKCA UKTA\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e \u003c\/span\u003e","brand":"Astroflame","offers":[{"title":"Default Title","offer_id":52552454766858,"sku":"Astro-AFPFPGRAPH","price":4.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0933\/2047\/8986\/files\/0f8569ad-62f9-4a67-9d4f-af9e47a1c1d1_07856a58-e75c-4eb2-98fe-7ebd2b17d2f5.jpg?v=1773956348","url":"https:\/\/prohotelsupplies.com\/products\/astroflame-pfp-fr-graphite-ce-ukca-cartridge-grey-310ml","provider":"ProHotelSupplies.com","version":"1.0","type":"link"}