{"product_id":"astroflame-pfp-fr-acrylic-ce-ukca-foil-white-600ml","title":"Astroflame PFP FR Acrylic - CE\/UKCA (Foil - White 600ml)","description":"\u003cp\u003e\u003cstrong\u003eAstroflame PFP FR Acrylic - CE\/UKCA (Foil - White 600ml)\u003c\/strong\u003e\u003c\/p\u003e \u003cspan itemprop=\"description\"\u003e\u003cp\u003e\u003cstrong\u003eKey Points:\u003c\/strong\u003e\u003c\/p\u003e  \u003cul\u003e \t\u003cli\u003eHigh end formula, certified worldwide\u003c\/li\u003e \t\u003cli\u003eClassified for fire sealing all types of construction and building service penetrations\u003c\/li\u003e \t\u003cli\u003eVery high sound insulation\u003c\/li\u003e \t\u003cli\u003eLow emissions - environmentally and user friendly\u003c\/li\u003e \t\u003cli\u003eSimple to apply with a smooth surface finish\u003c\/li\u003e \t\u003cli\u003ePermanently flexible will accommodate movement up to 12.5%\u003c\/li\u003e \t\u003cli\u003eNo priming necessary for application to most materials\u003c\/li\u003e \t\u003cli\u003eSuitable for most surfaces, included concrete, masonry, steel, gypsum, glass, plastics and most non-porous surfaces\u003c\/li\u003e \t\u003cli\u003eHardens quickly, tack free after 1 hour (the fire performance specification of the joint filler has been derived when the joint filler has been let to cure for a month)\u003c\/li\u003e \t\u003cli\u003e\n\u003cstrong\u003eExtended \u003c\/strong\u003eto 24 months storage time (under correct conditions)\u003c\/li\u003e \u003c\/ul\u003e  \u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e  \u003cp\u003eDesigned to prevent the spread of fire and smoke through joints and openings in fire rated walls and floors (including openings formed around building service penetrations); the Astro PFP FR Acrylic will also maintain the acoustic design performance.\u003cbr\u003e \u003cbr\u003e When subjected to atmospheric conditions, the sealant cures however, it will retain a degree of elasticity for joint movement. Under fire exposure, The Astro PFP FR Acrylic creates a robust fire seal by the formation of a durable intumescent char.\u003cbr\u003e \u003cbr\u003e The Astro PFP FR Acrylic can be used with a suitable filling material i.e. stone wool or Astro PFP FR backing material in order to secure correct width to depth ratio, and to reduce the shrinking of the sealant during curing. Minimum depth and maximum width of the joints are included in the installation instructions.\u003cbr\u003e \u003cbr\u003e When testing pipes, one can choose not to cap (or close) the pipe, or cap the pipe inside the furnace, or outside the furnace, or on both sides. The configuration chosen depends on the intended application of the pipe and\/or the installation environment.\u003c\/p\u003e  \u003cp\u003eThe code defining if a pipe is capped is stated after the fire classification. For instance, EI 60 C\/U which means the pipe was capped inside the furnace, and uncapped outside the furnace. The test configuration defines the approvals possible.\u003cbr\u003e \u003cbr\u003e Our engineering judgment based on EN 1366-3:2009 are:\u003c\/p\u003e  \u003ctable border=\"1\" cellpadding=\"0\" cellspacing=\"0\" style=\"width:100%;\"\u003e \t\u003ctbody\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd colspan=\"2\" style=\"text-align: left;\"\u003e\u003cstrong\u003eIntended use of pipe\u003c\/strong\u003e\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003e\u003cstrong\u003ePipe end condition\u003csup\u003e4\u003c\/sup\u003e\u003c\/strong\u003e\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd rowspan=\"2\" style=\"text-align: left;\"\u003eRainwater pipe, plastic\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eAt drainage\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eU\/U 1)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eNot at drainage\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eC\/C 2)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd rowspan=\"4\" style=\"text-align: left;\"\u003eDrainage or sewage pipe, plastic\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eVentilated drain\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eU\/U 1)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eUnventilated drain\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eU\/C 1)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eDrain w\/water trap\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eU\/C 1)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eNot at drainage\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eC\/C 2)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd colspan=\"2\" style=\"text-align: left;\"\u003ePipe in closed circuit (water, gas, air, electricity etc.)\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eC\/C 2) 3)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd colspan=\"2\" style=\"text-align: left;\"\u003eFlue gas recovery system pipe, plastic\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eU\/C 1)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd colspan=\"2\" style=\"text-align: left;\"\u003ePipe with open ends and 50cm length on both sides, plastic\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eU\/U 2)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd rowspan=\"2\" style=\"text-align: left;\"\u003ePipe supported by suspension system, metal\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eFire rated support\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eC\/U 1)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eNon-fire rated\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eU\/C 1)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd colspan=\"2\" style=\"text-align: left;\"\u003eWaste disposal shaft pipe, metal\u003c\/td\u003e \t\t\t\u003ctd style=\"text-align: left;\"\u003eU\/C 1)\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e    \u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" style=\"width:100%;\"\u003e \t\u003ctbody\u003e \t\t\u003ctr\u003e \t\t\u003c\/tr\u003e \t\t\u003ctr\u003e \t\t\t\u003ctd\u003e1) Suggested in EN 1366-3:2009. 2) Astroflames's judgment based on tests. 3) Metal pipes should have fire rated support. 4) U\/U classified fire seals cover C\/U, U\/C and C\/C. C\/U classified fire seals cover U\/C and C\/C. U\/C classified fire seals cover C\/C.\u003c\/td\u003e \t\t\u003c\/tr\u003e \t\u003c\/tbody\u003e \u003c\/table\u003e \u003cbr\u003e \u003cstrong\u003eSpecification:\u003c\/strong\u003e  \u003cul\u003e \t\u003cli\u003eSingle Foil Pack - 600ml\u003c\/li\u003e \t\u003cli\u003eColour: White\u003c\/li\u003e \u003c\/ul\u003e                  \u003cp\u003e\u003cb\u003eDownload and review any of the following information:\u003c\/b\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/pdf\/Astro_PFP_FR_Acrylic.pdf','_blank');\" type=\"button\" value=\"Product Data Sheet\"\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/pdf\/Astro_PFP_FR_Acrylic_SDS.pdf','_blank');\" type=\"button\" value=\"Safety Data Sheet\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003cstrong\u003eCertification\/Fire Test Reports:\u003c\/strong\u003e\u003c\/p\u003e \u003cimg align=\"left\" alt=\"CE Information\" height=\"32\" hspace=\"7\" src=\"https:\/\/www.astroflame.com\/images\/ce-ukca-icon-stormflame.gif\" vspace=\"40\" width=\"32\"\u003eCE Marked Documents\u003cbr\u003e 'DoP's are 'Declaration of Performance'\u003cbr\u003e 'CoC's are 'Certificate of Constancy of Performance'\u003cbr\u003e 'ETA' European Technical Assessment Sheet\u003cbr\u003e 'TDS' are 'Technical Data Sheet'\u003cbr\u003e 'UKTA' are UK Technical Assessment Sheet \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ce-data\/Astro-PFP-Acrylic-DoP.pdf','_blank');\" type=\"button\" value=\"DoP Astro PFP FR Acrylic\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ce-data\/Astro-PFP-FR-Acrylic-TDS.pdf','_blank');\" type=\"button\" value=\"Astro PFP FR Acrylic TDS\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ce-data\/CoC-Astro-PFP-FR-Acrylic.pdf','_blank');\" type=\"button\" value=\" CoC Astro PFP FR Acrylic CE\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ce-data\/Astro-PFP-FR-Acrylic-PS-ETA.pdf','_blank');\" type=\"button\" value=\"Astro PFP FR Acrylic ETA (Penetration) CE\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ce-data\/Astro-PFP-FR-Acrylic-Linear-ETA.pdf','_blank');\" type=\"button\" value=\"Astro PFP FR Acrylic ETA (Linear) CE\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ukca-data\/CoC-UKCA-Astro-PFP-FR-Acrylic.pdf','_blank');\" type=\"button\" value=\" CoC Astro PFP FR Acrylic UKCA\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ukca-data\/Astro-PFP-FR-Acrylic-Penetration-UKTA.pdf','_blank');\" type=\"button\" value=\"Astro PFP FR Acrylic UKCA (Penetration) UKTA\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cp\u003e\u003c\/p\u003e  \u003cform\u003e\u003cinput class=\"MyButton\" onclick=\"window.open('https:\/\/www.astroflame.com\/ukca-data\/Astro-PFP-FR-Acrylic-Linear-UKTA.pdf','_blank');\" type=\"button\" value=\"Astro PFP FR Acrylic UKCA (Linear) UKTA\"\u003e\u003c\/form\u003e  \u003cp\u003e\u003c\/p\u003e \u003c\/span\u003e","brand":"Astroflame","offers":[{"title":"Default Title","offer_id":52548210655498,"sku":"Astro-AFPFPACW\/FOIL","price":5.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0933\/2047\/8986\/files\/39517262-e316-4a80-923f-25e629e0e7f4_bf16f3f3-38fc-4fa5-b4d7-02b8fa44a2e9.jpg?v=1773956344","url":"https:\/\/prohotelsupplies.com\/products\/astroflame-pfp-fr-acrylic-ce-ukca-foil-white-600ml","provider":"ProHotelSupplies.com","version":"1.0","type":"link"}